. The
Containerised system is built into a 3 compartment ISO Container.There
is a 100 KVA diesel generator in one end in a fully acoustic compartment
which also has storage space for the centrifugal pump. The centre
compartment houses the umbilical for the cannon, the hydraulic power
pack. and a storage frame for the cannon.
The control room is at the other end and
houses the CCTV monitoring and computerised control system.
SPECIFICATION:
Generator:100 KVA 415 V 50 HZ Diesel Driven
Manway
Cannon:All stainless steel with Chemical protection
Centrifugal Pump:950 litres/minute (251 USG minute) @ 18 Bar (261 psi) Diesel or water 80 Deg C
Maximum Hydraulic Power:0.75 kW fixed displacement flow controlled.
Control:Manual joystick or automatic software control.
Gas
Detection:Oxygen and LEL detection with alarm and auto shutdown.
Container:Accoustic engine compartment, Insulated air conditioned
control room Umbilical:Standard 100 Mtr optional 150 Mtr extension.
Cannon
operation:Horizontal tank shell or roof operation.
CCTV:Real time recording and playback via DVD recorder.
Software:Interactive software control and monitoring with graphical
representation
|
|
|
|
|
|
|
|
|
|
|
CONT203/SA |
|
|
|
|
|
700V3 NS/FP/E/GD |
|
|
|
|
|
NES-CP-ST-45 |
|
|
|
|
|
PWR/SRU/45
|
|
|
|
|
|
MCUMB/100 |
|